877-888-5910
About this product


1. Optimized for continuous operation at +37 °C, +25 °C and +10 °C, perfect for incubation at +15~+37 °C

2. Silent long shaft circulating fan for safety and uniform temperature distribution

3. SUS plate-type evaporator, frost-free reliable and efficient operation guaranteed

4. Choose between power-on modes of standby and auto-restart after power failure

5. Automatic defrosting capibility

6. Absolute temperature calibration (ATC) , units of  Celsius and Fahrenheit temperature;

7. Timer for auto start-up or shut-down, temperature program up to 6 segments and 99 cycles

  • Quiet, precise and efficenctstepper valve hot gas bypassing and PID temperature control guarantee precise temperature regulation over the range for stability up to ±0.2 °C, as well as for accurate control of the cooling capacity which significantly improves the efficiency of the refrigeration system
  • Uniform air movement and temperature distribution, silent long shaft circulating fan and the unique design of air circulation provide uniform air movement, improved temperature distribution, minimize the effect of localized temperature changes and protect seedling, seeds, insects or small animal from being blown
  • Plate type evaporator frost free operation, equipped with name brand compressor, SUS plate-type evaporator and environment friendly refrigerant of R134a for cooling. Reliable, efficient and fronst free operation is guaranteed
  • Safety features, including independent cabinet over temperature protection, motor overheating protection, maximum and minimum temperature cutout and alarm
  • Auto-restart or standby after power failure, choose between power-on modes of standby and auto-restart after power failure for additional safety and uninterrupted operation
  • Automatic defrost capability gurantted for long term, lower temperature uninterrupted operation
  • Adjustable shelves and easy for cleaning, coated cabinet interior and adjustable shelves of stainless steel make the daily clean easy for corrosive-resistant long-life operation and, for flexible space and height
  • Options, RS232 interface for data acquisition and remote monitoring and control, operator light






Model

UXP8111-IR150

Temperature Range

°C (°F)

4 ~ 65 (39.2 ~ 149.0)

Temperature Stability

±°C (°F)

0.2 (0.4)

Temperature Uniformity

°C (°F)

2.0 (3.6)

ACC Temperature

°C (°F)

40 (104)

Temperature Programming

6 segments×99h59min, 99 cycles

Timer

Timers for automatic start-up and automatic shut-down

Safety

Temperature sensor open/short cut off and alarm,

Independent STB cutoff and warning, door-open alarm

High-temperature cut off and low temperature alarm

Utility Function

Standby or auto-restart after power failure

Absolute temperature calibration, operator light

EMC for USA and Canada

Class A (for operation only on networks without connected domestic areas)

Duty Cycle

Continuous

Installation Conditions

Indoor use, and altitude: 2,000 meters

Ambient Temperature Range: 16 °C to 32 °C (class N)

Humidity: 75% RH at or below 32 °C

Mains supply fluctuations: Rated Voltage ±10%

Installation category: II **, Pollution Degree: 2 ***, Class of Equipment: I

Interior Material

SUS 430 stainless steel coated white

Housing Materials

SPCC steel with powder coating

Observation Window

IR models only

Compressor

W

185

Refrigerant

HFC134a

Heater Wattage

W

450

Effective Capacity

L (cf)

150 (5.30)

Interior Size (WDH)

mm (in)

550×450×615 (21.6×17.8×24)

Overall Dimensions (WDH)****

mm (in)

705×620×1090 (27.8×24.4×42.9)

Shelves*****

EA

2/5

Packing Size (WDH)

mm (in)

790×830×1320 (31.1×32.7×52.0)

Net Weight

Kg (lbs)

96 (211.6)

Gross Weight

Kg (lbs)

114 (251.3)

Voltage and Frequency

115V~, 60Hz

Current Draw

A

8.5

*      Measured under 20 °C ambient conditions, higher ambient may degrade the minimum temperature and cooling capacity.

**    Installation category (overvoltage category) defines the level of transient overvoltage which the equipment is designed to withstand safely. It depends on the nature of the electricity supply and its overvoltage protection means. For example, in CAT II which is the category used for equipment in installations supplied from a supply comparable to public mains such as hospital and research laboratories and most industrial laboratories, the expected transient overvoltage is 250 V for a 230 V supply and150 V for a 115 V supply.

*** Pollution degree describes the amount of conductive pollution present in the operating environment. Pollution degree 2 assumes that normally only non-conductive pollution such as dust occurs with exception of occasional conductivity caused by condensation.

**** Maximum shelf and unit capacity is based on mechanical capabilities. Note that with heavy load the heat-up/cool-down time of the unit will increase, andt emperature performance might be impacted. A load below 30% of max. capacity, with even distribution in the chamber will provide optimal conditions.

*****Including feet / caster

Write a review

Please login or register to review

0 reviews / Write a review

{{ selectSpec[item.code]?.label }}

5.3CF Precision Low Temperature BOD Refrigerated Incubator Biochemical Incubator Frost Free 150L ±0.2°C

  • Model #: 68IJJTBQ
  • Availability: Out of stock
  • Before: $3,299.00
  • Now: $1,979.99


Website Security Test