MADE IN THE USA<
Online adaptive water-level control
Automatically adds water, offline & online
Safety overflow drain
The stainless steel wet dust collector excels at capturing combustible/hazardous dust from your plant air. The blower draws air through diversiTech's proprietary water-tree baffle design, creating a cascading water effect that removes particles as small as 3 microns from the airstream. Dust is filtered through contact with water droplets and contained in the bottom of the collector for safe removal at necessary maintenance intervals. Water levels are automatically controlled with valves and sensors, including interlock functions to meet NFPA and OSHA codes.
NFPA 484 Compliant
In 2015, NFPA updated the 484 standards requiring an interlocked offline vent fan, to prevent a build-up of hydrogen gas. Optional HEPA filters also now require a high-temperature alert. Diversitech's CSA/UL certified control panel now supports:
- Offline Vent Fan included
- HEPA Filter high-temperature alert (option)
100% Duty Cycle
The WX Collector's new ultrasonic water sensor monitors and automatically adds water as needed, even while the machine is in operation.
- Oline adaptive water-level control
- Automatically adds water, offline & online
- Safety overflow drain
Benefits:
- Capture-at-source for Cleaner Air
- Complies with NFPA guidelines for Combustible Dust
Features:
- Ultrasonic water level sensor
- NEMA 4x control panel w/LCD display
- Mainline Interlock Switch
- Anti-Corrosion stainless steel #304 construction
- High efficiency, non-sparking blower wheel
- Transparent Lexan doors, with easy access clasps
- Low-cost mist eliminator after filters
Ideal Applications:
- Aluminum
- Magnesium
- Titanium
- Grinding & Deburring
- Sanding & Finishing
- Powder Mixing
- Buffing & Polishing
- Wide Belt Sanding
Model | Inlet Collar Diameter (in.) | Footprint | Net Weight (lbs.) | Water | Shipping Dimensions (in.) | Gross Weight (Per Palette) (lbs.) | |||||||||
Length [b] | Height [C] | Width [d] | Supply (in.) | Drain (in.) | Length [b] | Height [C] | Width [d] | ||||||||
WX-1200 | 6 | 34 | 86 | 32 | 395 | 1/4" NPT | 3/4" NPT | 48 | 68 | 48 | 500 | ||||
WX-3000 | 10 | 47 | 109 | 44 | 738 | 1/4" NPT | 3/4" NPT | 60 | 84 | 60 | 900 | ||||
WX-5000 | 16 | 61 | 117 | 57 | 923 | 1/4" NPT | 3/4" NPT | 80 | 106 | 80 | 1200 | ||||
WX-6500 | 16 | 67 | 129 | 67 | 1185 | 1/4" NPT | 3/4" NPT | 75 | 40 | 101 | 38 | 74 | 64 | 1500 | 250 |
1. Water Level is marked on each unit.
Model | Water Fill System | Nominal Airflow (CFM) | Tank Capacity (Gallons) | Motor (H.P.) | Power | Noise @5ft. (dB) | |||
Phase (hz) | @230V (amps) | @460V (amps) | @575V (amps) | ||||||
WX-1200 | auto | 1200 | 16 | 3.0 | 3P / 60Hz | 9.6 | 4.8 | 3.9 | 74 |
WX-3000 | auto | 2000-3500 | 40 | 5.0 | 3P / 60Hz | 15.2 | 7.6 | 6.1 | 78 |
WX-5000 | auto | 3000-5000 | 80 | 10.0 | 3P / 60Hz | 28.0 | 14.0 | 11.0 | 78 |
WX-6500 | auto | 4000-6500 | 80 | 15.0 | 3P / 60Hz | 34.0 | 16.9 | 14.0 | 80 |
1. For 1200, Airflow @ 2" external static pressure
2. For WX-3000, WX-5000, WX-6500, Airflow @ 2.5" external static pressure