1. Service conditions: altitude no more than 1000M
2. Ambient temperature: - 20°C-50°C
3. Relative humidity: 45% - 95%
4. Voltage range: AC 110V
5. Heating head temperature: 260 ± 5°C
6. Safety index: insulation resistance is not less than 1m Ω
7. Leakage current: ≤ 5mA (AC RMS)
1.Fix implements and heating terminal
Put the implements on the bracket.Choose the terminal as the diameter of the pipe,then tight the bolt.Normally,small terminal is at front, and big size at the back.
2.Turn on plug power connector(power need protect grounding).Red light on is heating ,the,red light off is heating completed
3.Pipe melting
Use pipe cutter to cut the pipe ,put pipe into heat terminal,operate as belowed table ,take out the pipe when reaching the heating time ,connect this pipe with the fitting till flange formed
mbient temperature | - 20°C-50°C |
Relative humidity | 45% - 95% |
Voltage range | AC 220v-230v |
Heating head temperature | 260 ± 5°C |
Leakage current | ≤ 5mA (AC RMS) |